Belgaum, Karnataka, India · Exporting to Africa & the Gulf +91 87490 59957sales@flowtexheatexchangers.comالعربية

PRODUCT SUPPORT

Frequently Asked Questions About Heat Exchangers

Explore practical answers to common product selection, operation, material and maintenance questions. Final equipment selection should be confirmed against the project duty and approved technical specifications.

PRODUCT FAQ

Shell & Tube Heat Exchangers

Shell and tube heat exchangers transfer heat between two fluid circuits through a tube bundle housed inside a shell.

What is a shell and tube heat exchanger?

A shell and tube heat exchanger is a thermal device in which one fluid flows through a tube bundle and another flows around it within the shell. Heat passes through the tube walls without the two fluid streams needing to mix.

How do I select a shell and tube heat exchanger?

Selection should consider heat duty, flow rates, inlet and outlet temperatures, design pressures, fluid properties, fouling tendency, materials, installation space and cleaning requirements.

Which materials are used to manufacture shell and tube heat exchangers?

Materials may include carbon steel or stainless steel for pressure-containing parts and copper, stainless steel or other suitable alloys for tubes. Final materials depend on the design and service conditions.

What is the difference between fixed tube-sheet, U-tube and floating tube-sheet designs?

These designs differ in thermal expansion accommodation and access for inspection or cleaning. The appropriate construction depends on duty and maintenance requirements.

Can a shell and tube heat exchanger be customised?

A unit can be specified around the thermal duty, fluids, pressure and temperature conditions, materials, connections, installation envelope and applicable design requirements.

What information should I provide for a quotation?

Provide both fluids, flow rates, inlet and target outlet temperatures, operating and design pressures, fouling or corrosion concerns, material preferences, connections, applicable codes and available space.

PRODUCT FAQ

Marine Application Oil Coolers

Marine oil coolers remove heat from oil used in marine hydraulic, lubrication and related systems.

What is a marine application oil cooler?

A marine oil cooler transfers heat from oil to a cooling medium to help keep oil within the required operating temperature range.

Why is corrosion resistance important in marine oil coolers?

Marine equipment may encounter seawater and humid, saline conditions. Materials should be selected for the actual cooling medium and service environment.

What is the purpose of a sacrificial zinc anode?

A sacrificial zinc anode is intended to help mitigate seawater-related corrosion and is gradually consumed, so it requires periodic inspection and replacement.

Can marine oil coolers use seawater?

Some designs use seawater directly while others use a closed-loop fresh-water circuit. Compatibility depends on design, materials and system requirements.

What maintenance is required?

Depending on the design, maintenance may include inspection for leaks, fouling, corrosion and pressure drop, plus cleaning as directed by the manufacturer.

What information is needed to specify a marine oil cooler?

Share oil type and flow, heat duty, oil inlet and outlet temperatures, cooling-medium conditions, pressure limits, materials, connections and installation dimensions.

PRODUCT FAQ

Duplex Oil Coolers

A duplex oil cooler typically uses two cooler sections with a changeover arrangement to support servicing flexibility.

What is a duplex oil cooler?

A duplex oil cooler has two cooler sections and a changeover arrangement, designed to allow one section to be serviced while the other operates where the system permits.

What is the advantage over a simplex oil cooler?

A duplex arrangement can reduce the need to stop a system for routine cooler maintenance by allowing changeover to the alternate cooler.

How does the changeover valve work?

The changeover mechanism directs oil through the selected cooler section. Operation should follow the approved design and manufacturer instructions.

Where are duplex oil coolers considered?

They may suit lubrication and hydraulic systems where operational continuity and maintenance flexibility are important.

Can a duplex oil cooler be customised?

Configuration can be specified around flow, heat duty, pressure and temperature limits, fluid properties, materials, connections and changeover requirements.

What information is needed for a quotation?

Provide oil flow and type, temperatures, cooling-medium details, heat duty, pressures, materials, connection sizes, changeover needs and installation constraints.

PRODUCT FAQ

Plate Type Heat Exchangers

Plate type heat exchangers transfer heat between fluid circuits through thin plates in a compact arrangement.

What is a plate type heat exchanger?

It transfers heat between two fluid streams flowing through alternate channels formed by a stack of plates that keep the streams separated.

What are the benefits of a plate heat exchanger?

Depending on design, benefits can include a compact footprint, efficient heat transfer, modular capacity and access for inspection or cleaning.

Which fluids can be used?

Suitability depends on temperature, pressure, viscosity, cleanliness, corrosiveness and compatibility with plate and gasket materials.

How do I select the correct size?

Provide flow rates, fluid properties, inlet and target outlet temperatures, heat duty, pressure-drop limits, operating pressures, fouling tendency and installation space.

Can plate heat exchangers be used for oil cooling?

They can be used for oil cooling when oil properties, viscosity, pressure, temperature and materials are compatible with the selected design.

What maintenance is needed?

Depending on the model, maintenance may include leak checks, pressure-drop monitoring, plate and gasket inspection and cleaning per manufacturer procedures.

PRODUCT FAQ

Air Oil Coolers

Air oil coolers use ambient air, often moved by a fan, to remove heat from circulating oil.

What is an air oil cooler?

An air oil cooler transfers heat from oil through a heat-exchanger core to ambient air. A fan may provide forced airflow.

Where are air oil coolers used?

They are considered for hydraulic power packs, lubrication systems and industrial machinery where oil temperature needs control.

How do I size an air oil cooler?

Sizing requires heat-rejection duty, oil flow and properties, oil inlet and target outlet temperatures, maximum ambient temperature, airflow and allowable pressure drop.

Does ambient temperature affect performance?

Yes. Higher ambient air temperature reduces the temperature difference available for heat transfer and may reduce cooling performance.

What should I check before replacing a cooler?

Check duty, flow, pressure, connections, dimensions, mounting, electrical supply, fan requirements and allowable pressure drop.

Can an air oil cooler be customised?

Configuration may be selected around cooling duty, oil flow, ambient temperature, airflow, mounting, connections and available space, subject to engineering limits.

PRODUCT FAQ

Fin Tube Heat Exchangers & Steam Radiators

Fin tube heat exchangers use extended fin surfaces to improve heat transfer, particularly when air is one of the fluids.

What is a fin tube heat exchanger?

It uses tubes with extended fin surfaces to increase the area available for heat transfer between the tube-side fluid and surrounding air or process.

What is a steam radiator used for?

A steam radiator or steam air heater transfers heat from steam to an air stream for a specified process-heating requirement.

Why are fins used on heat exchanger tubes?

Fins increase surface area and can improve heat transfer where air-side heat transfer is a limiting factor.

What information is needed to specify a fin tube heat exchanger?

Provide heating or cooling medium, flow and operating conditions, air volume, entering and target leaving air temperatures, pressure-drop limits, materials and dimensions.

Can fin tube heat exchangers be used in dryer systems?

They may be used for dryer-related air heating or cooling when the thermal duty, airflow, medium and operating conditions suit the design.

Which fin and tube materials are available?

Material options depend on the product design and service conditions. Confirm available tube and fin materials and corrosion compatibility with the manufacturer.

PRODUCT FAQ

Compressor Intercoolers & Aftercoolers

Intercoolers remove heat between compression stages; aftercoolers reduce compressed-air or gas temperature after final compression.

What is the difference between an intercooler and an aftercooler?

An intercooler cools compressed gas between compression stages. An aftercooler cools it after the final compression stage.

Why is cooling required in compressor systems?

Compression raises gas temperature. Cooling can help meet downstream temperature requirements and may support moisture condensation in suitable systems.

How do I select a compressor cooler?

Consider gas composition, flow, inlet and target outlet temperatures, operating and design pressure, allowable pressure drop, cooling-medium conditions and materials.

Can shell and tube construction be used?

Shell and tube construction is one possible configuration. Suitability depends on gas and cooling medium, pressure, thermal duty and maintenance requirements.

What operating data should I provide?

Provide compressor stage, gas composition, flow rate, inlet temperature and pressure, target outlet temperature, cooling medium, pressure-drop limits and connection details.

Can an aftercooler remove moisture from compressed air?

Cooling can cause water vapour to condense when conditions cross the dew point. Effective moisture removal also requires suitable separation and drainage equipment.

PRODUCT FAQ

Condensers & Evaporators

Condensers and evaporators support heat-transfer duties involving condensation or evaporation, subject to process design requirements.

What does an industrial condenser do?

A condenser removes heat from a vapour so it can change into liquid. The design depends on vapour properties, pressure, cooling medium and required duty.

What does an evaporator do?

An evaporator transfers heat to a liquid to promote vaporisation. Selection depends on the process fluid, operating pressure, temperature and thermal duty.

How do I select a condenser or evaporator?

Provide fluid composition, flow rate, phase-change conditions, inlet and outlet temperatures, operating/design pressure, cooling or heating medium, materials and allowable pressure drop.

Can these products be designed to customer specifications?

The configuration can be evaluated against process conditions, required duty, materials, installation constraints and applicable design requirements.

What information is required for a quotation?

Share process data, flow rates, pressure and temperature conditions, heat duty, material requirements, connection details and applicable codes.

How is performance verified?

Performance and inspection requirements should be agreed in the project specification and verified using the applicable approved design and test procedures.

NEED TECHNICAL GUIDANCE?

Discuss your heat-transfer requirement

Share your process data, operating conditions and installation constraints with Flowtex Engineers for a technical review.

Request a Quote